SSG5000A RF Signal Generator User Manua
l
SSG5000A User Manual 28
the process.
Step Sweep
The step sweep state is on by default. Click the slide to switch the on-off state. Click
to enter the parameter setting menu of step sweep.
Note:
The step sweep and list sweep are mutually exclusive. One will shut off
automatically when the other is on.
1) Start Freq: Initial frequency set point of the sweep.
2) Stop Freq: Final frequency set point of the sweep.
3) Start Level: Initial amplitude level set point of the sweep.
4) Stop Level: Final amplitude level set point of the sweep.
5) Dwell time: The interval time between two sweep points.
6) Sweep points: The number of points in a sweep. Every point is interpolated between
the start parameter and stop parameter.
7) Sweep shape: Click the drop-down box, Sawtooth and Triangle can be selected
⚫
Sawtooth: Sweep period is always from the start frequency or start level to the stop
frequency or stop level. The sweep sequence is similar to a "Sawtooth wave".
⚫
Triangle: Sweep period is always from the start frequency or start level to the stop
frequency or stop level, and then return back to the start frequency or start level. The
sweep sequence is similar to a "triangle wave".
8) Sweep Space: Click the drop-down box, linear and log can be selected.
9) Freq Step Linear/Freq Step Log: It is used to set the step value of each sweep points
and is associated with “Sweep points”. It will change the “Sweep points” when setting
step value or change the step value when setting “Sweep points”.
Note:
Level sweep only support the line sweep mode.
List sweep
The list sweep state is off by default. Click the slide to switch the on-off state. Click
to