SSG5000A RF Signal Generator User Manua
l
SSG5000A User Manual 96
(2)No modulation on the RF output
-
Check that the signal cable is securely connected to the corresponding [RF OUTPUT 50
Ω] port.
-
Check the cable for damage.
-
Check that both the MOD and RF button backlights are lit and that the modulation
switch needs to be turned on.
-
Check if the modulation parameters are appropriate and modulate the modulation
parameters appropriately.
-
If an external modulation source is used, make sure that the external source is
connected correctly and has an output and should work within the range established by
the source.
4
.
Sweep is abnormal:
(1)Scanning stagnation
The user interface frequency zone/amplitude zone displays a scan progress bar indicating
that a scan operation is in progress. If there is stagnation, check the points.
-
Open at least one scan type: Select Frequency, Amplitude, or Frequency & Amplitude
according to the SWEEP scan type status.
-
If the single scan mode is enabled, a single scan is performed when the single software
meets the trigger condition.
-
If the scan trigger mode is not automatic trigger, press SWEEP trigger mode to
automatically trigger to determine if the scan trigger is missing and the scan is blocked.
-
If the point trigger mode is not automatic trigger, it is automatically triggered by the
SWEEP trigger mode to determine if the point trigger is missing and the scan is blocked.
-
Determine if the dwell time setting is too large or too small for the scan to be visible.