Spare parts/accessories
13.5 IR analyzer units
ULTRAMAT 23
208
Manual, 3/2016, A5E37100388-003
Part
No.
Designation
Order No.
Remarks
1 *)
IR source
C79451-A3468-
B206
3 *)
Chopper
C79451-A3468-
B516
3 *)
Chopper
A5E35984159
Only variant -B06 'Cleaned for O
2
'
4
Plate with threaded bolts and
windows
C79451-A3468-
B514
4
Plate with threaded bolts and
windows
CA5E35984162
Only variant -B06 'Cleaned for O
2
'
5.1
Analyzer chamber
C79451-A3468-
B235
Analyzer chamber 6 mm
5.1
Analyzer chamber
A5E35982178
Analyzer chamber 6 mm;
only variant -B06 'Cleaned for O
2
'
6.1
Gas filter
C79451-A3458-
B500
For CO
6.1
Gas filter
A5E35983013
For CO; only variant -B06 'Cleaned for O
2
'
7 *)
Receiver chamber
C79451-A3468-
B530
For CO
7 *)
Receiver chamber
A35984307
For CO; only variant -B06 'Cleaned for O
2
'
5.2
Analyzer chamber with O-ring
C79451-A3468-
B233
Analyzer chamber 60 mm
5.2
Analyzer chamber with O-ring
A5E35982163
Analyzer chamber 60 mm;
only variant -B06 'Cleaned for O
2
'
5.2.1 O-ring
C71121-Z100-A99
5.2.1 O-ring
A5E35980590
Only variant -B06 'Cleaned for O
2
'
6.2
Gas filter
C79451-A3468-
B542
For NO
6.2
Gas filter
A5E35983036
For NO; only variant -B06 'Cleaned for O
2
'
8
Optical filter
C79451-A3458-
B103
For NO **)
9 *)
Receiver chamber
C79451-A3468-
B520
For NO (channel 1)
9 *)
Receiver chamber
A5E35983178
For NO (channel 1);
only variant -B06 'Cleaned for O
2
'
*) Following replacement of this part, special work is required which can only be carried out by qualified personnel trained
for this task, for example temperature compensation, basic electronic adjustment etc.
**) Following replacement of this part, the water vapor cross-sensitivity must be checked.
Содержание ULTRAMAT 23
Страница 2: ......
Страница 10: ...Table of contents ULTRAMAT 23 10 Manual 3 2016 A5E37100388 003 Index 239 ...
Страница 18: ...Safety instructions 2 2 Analyzers in hazardous areas ULTRAMAT 23 18 Manual 3 2016 A5E37100388 003 ...
Страница 66: ...installation ULTRAMAT 23 66 Manual 3 2016 A5E37100388 003 ...
Страница 88: ...Commissioning 6 5 System setup with several analyzers in parallel ULTRAMAT 23 88 Manual 3 2016 A5E37100388 003 ...
Страница 147: ...Functions 8 4 Configuration ULTRAMAT 23 Manual 3 2016 A5E37100388 003 147 ...
Страница 160: ...Functions 8 5 Automatically executed functions ULTRAMAT 23 160 Manual 3 2016 A5E37100388 003 ...
Страница 164: ...Application note 9 1 H2S sensor with small measuring range ULTRAMAT 23 164 Manual 3 2016 A5E37100388 003 ...
Страница 184: ...Taking out of operation and disposal 12 2 Scrapping the analyzer ULTRAMAT 23 184 Manual 3 2016 A5E37100388 003 ...
Страница 194: ...Spare parts accessories 13 5 IR analyzer units ULTRAMAT 23 194 Manual 3 2016 A5E37100388 003 ...
Страница 195: ...Spare parts accessories 13 5 IR analyzer units ULTRAMAT 23 Manual 3 2016 A5E37100388 003 195 ...
Страница 196: ...Spare parts accessories 13 5 IR analyzer units ULTRAMAT 23 196 Manual 3 2016 A5E37100388 003 ...
Страница 229: ...Appendix A 4 Returned delivery ULTRAMAT 23 Manual 3 2016 A5E37100388 003 229 ...
Страница 230: ...Appendix ULTRAMAT 23 230 Manual 3 2016 A5E37100388 003 ...
Страница 238: ...List of abbreviations C 1 List of abbreviations ULTRAMAT 23 238 Manual 3 2016 A5E37100388 003 ...