Spare parts/accessories
13.5 IR analyzer units
ULTRAMAT 23
Manual, 3/2016, A5E37100388-003
199
Part
No.
Designation
Order No.
Remarks
5
Analyzer chamber
A5E35982182
2 mm; only variant -B06 'Cleaned for O
2
'
6
Gas filter
C79451-A3458-
B500
For CO
6
Gas filter
A5E35983013
For CO; only variant -B06 'Cleaned for O
2
'
6
Gas filter
C79451-A3458-
B508
For SO
2
6
Gas filter
A5E35983026
For SO
2
; only variant -B06 'Cleaned for O
2
'
6
Gas filter
C79451-A3468-
B541
For CO
2
; smallest MR <5%
6
Gas filter
A5E35983032
For CO
2
; smallest MR <5%;
only variant -B06 'Cleaned for O
2
'
6
Gas filter
C79451-A3468-
B542
For CH
4
; smallest MR <2%
6
Gas filter
A5E35983036
For CH
4
; smallest MR <2%;
only variant -B06 'Cleaned for O
2
'
6
Gas filter
C79451-A3468-
B553
For C
6
H
14
6
Gas filter
A5E35983044
For C
6
H
14
; only variant -B06 'Cleaned for O
2
'
7 *)
Receiver chamber
C79451-A3468-
B525
For CO; smallest MR <5%
7 *)
Receiver chamber
A5E35983110
For CO; smallest MR <5%;
only variant -B06 'Cleaned for O
2
'
7 *)
Receiver chamber
C79451-A3468-
B528
For CO; smallest MR ≥5%
7 *)
Receiver chamber
A5E35983122
For CO; smallest MR ≥5%;
only variant -B06 'Cleaned for O
2
'
7 *)
Receiver chamber
A5E34729715
For CO, MLFB 7MB2355
7 *)
Receiver chamber
C79451-A3468-
B536
For CO
2
; smallest MR <1000 vpm
7 *)
Receiver chamber
A5E35983141
For CO
2
; smallest MR <1000 vpm;
only variant -B06 'Cleaned for O
2
'
7 *)
Receiver chamber
C79451-A3468-
B526
For CO
2
; smallest MR ≥1000
vpm
7 *)
Receiver chamber
A5E35983146
For CO
2
; smallest MR ≥1000
vpm;
only variant -B06 'Cleaned for O
2
'
7 *)
Receiver chamber
C79451-A3468-
B527
For CH
4
; smallest MR <20%
7 *)
Receiver chamber
A5E35983151
For CH
4
; smallest MR <20%;
only variant -B06 'Cleaned for O
2
'
7 *)
Receiver chamber
C79451-A3468-
B529
For CH
4
; smallest MR ≥20%
7 *)
Receiver chamber
A5E35983152
For CH
4
; smallest MR ≥20%;
only variant -B06 'Cleaned for O
2
'
7 *)
Receiver chamber
C79451-A3468-
B537
For C
2
H
4
7 *)
Receiver chamber
A5E35983172
For C
2
H
4
; only variant -B06 'Cleaned for O
2
'
Содержание ULTRAMAT 23
Страница 2: ......
Страница 10: ...Table of contents ULTRAMAT 23 10 Manual 3 2016 A5E37100388 003 Index 239 ...
Страница 18: ...Safety instructions 2 2 Analyzers in hazardous areas ULTRAMAT 23 18 Manual 3 2016 A5E37100388 003 ...
Страница 66: ...installation ULTRAMAT 23 66 Manual 3 2016 A5E37100388 003 ...
Страница 88: ...Commissioning 6 5 System setup with several analyzers in parallel ULTRAMAT 23 88 Manual 3 2016 A5E37100388 003 ...
Страница 147: ...Functions 8 4 Configuration ULTRAMAT 23 Manual 3 2016 A5E37100388 003 147 ...
Страница 160: ...Functions 8 5 Automatically executed functions ULTRAMAT 23 160 Manual 3 2016 A5E37100388 003 ...
Страница 164: ...Application note 9 1 H2S sensor with small measuring range ULTRAMAT 23 164 Manual 3 2016 A5E37100388 003 ...
Страница 184: ...Taking out of operation and disposal 12 2 Scrapping the analyzer ULTRAMAT 23 184 Manual 3 2016 A5E37100388 003 ...
Страница 194: ...Spare parts accessories 13 5 IR analyzer units ULTRAMAT 23 194 Manual 3 2016 A5E37100388 003 ...
Страница 195: ...Spare parts accessories 13 5 IR analyzer units ULTRAMAT 23 Manual 3 2016 A5E37100388 003 195 ...
Страница 196: ...Spare parts accessories 13 5 IR analyzer units ULTRAMAT 23 196 Manual 3 2016 A5E37100388 003 ...
Страница 229: ...Appendix A 4 Returned delivery ULTRAMAT 23 Manual 3 2016 A5E37100388 003 229 ...
Страница 230: ...Appendix ULTRAMAT 23 230 Manual 3 2016 A5E37100388 003 ...
Страница 238: ...List of abbreviations C 1 List of abbreviations ULTRAMAT 23 238 Manual 3 2016 A5E37100388 003 ...