Example:
A flow velocity of 3 m/s (10 ft./sec.) (V) in a sensor with a diameter reduction from DN 100 to
DN 80 (4" to 3") (d
1
/d
2
= 0.8) gives a pressure drop of 2.9 mbar (0.04 psi).
4.1.3
Mounting the sensor
1. Install gaskets.
2. Ensure connection flange has a smooth surface and is in line with sensor.
Gaskets are recommended but not included in water meter delivery.
Advice for gasket selection:
● Only use flat rubber gaskets.
● Thickness 1 to 6 mm (0.0 to 0.02 ft) dependent on gap/tolerance.
● Inner diameter must be larger than bore of water meter.
● Material should be compatible with process fluid.
● Hardness should be maximum 75 Shore A.
Maximum allowable torques
Standard bolts must be well lubricated and tightened evenly around gasket.
Leakage/damage to water meter or piping may arise if bolts are overtightened.
Torque calculations
Installing/Mounting
4.1 Sensor installation
SITRANS MAG 8000
22
Operating Instructions, 11/2018, A5E03071515-AE
Содержание SITRANS F M MAG 8000
Страница 10: ...Introduction 1 3 Further Information SITRANS MAG 8000 10 Operating Instructions 11 2018 A5E03071515 AE ...
Страница 16: ...Description 3 4 Benefits SITRANS MAG 8000 16 Operating Instructions 11 2018 A5E03071515 AE ...
Страница 56: ...Commissioning 6 6 Data protection SITRANS MAG 8000 56 Operating Instructions 11 2018 A5E03071515 AE ...
Страница 74: ...Operation 7 6 Battery powered operation SITRANS MAG 8000 74 Operating Instructions 11 2018 A5E03071515 AE ...
Страница 90: ...Troubleshooting FAQs 9 3 Flow simulation SITRANS MAG 8000 90 Operating Instructions 11 2018 A5E03071515 AE ...
Страница 164: ...Index SITRANS MAG 8000 164 Operating Instructions 11 2018 A5E03071515 AE ...