PW = pulse width
Note
The calculated numbers of pulses are an average of the measuring period.
The factory value of pulse width shall be 10ms by if Z option L70-L74 for pulse A or L90-L94
for pulse B selected.
For MAG 8000 CT please see definition of Q3 flow rates in the certificates for OIML R 49 or
MI 001.
Net flow output
The MAG 8000 has a special net pulse output that includes bi-directional flow calculations.
The example shows that over time, the net pulse output indicates the bi-directional totalizer
as calculated internally. The same principle applies for forward and reverse flow calculation.
By changing the status of the pulse output, the internal pulse calculator will be reset.
Flow
Net totalizer in
meter display
(Bi-directional)
Pulse output forward Uni-directional
mode
Volume [m
3
]
Pulse output net forward Bi-direction‐
al mode
Volume [m
3
]
Volume [m
3
]
Internal calcula‐
tion
Delivered volume Internal calcula‐
tion
Delivered volume
0
-
0
0
0
10
-
10
0
10
−2
-
0
-12
0
Technical data
10.6 Output characteristics
SITRANS MAG 8000
100
Operating Instructions, 11/2018, A5E03071515-AE
Содержание SITRANS F M MAG 8000
Страница 10: ...Introduction 1 3 Further Information SITRANS MAG 8000 10 Operating Instructions 11 2018 A5E03071515 AE ...
Страница 16: ...Description 3 4 Benefits SITRANS MAG 8000 16 Operating Instructions 11 2018 A5E03071515 AE ...
Страница 56: ...Commissioning 6 6 Data protection SITRANS MAG 8000 56 Operating Instructions 11 2018 A5E03071515 AE ...
Страница 74: ...Operation 7 6 Battery powered operation SITRANS MAG 8000 74 Operating Instructions 11 2018 A5E03071515 AE ...
Страница 90: ...Troubleshooting FAQs 9 3 Flow simulation SITRANS MAG 8000 90 Operating Instructions 11 2018 A5E03071515 AE ...
Страница 164: ...Index SITRANS MAG 8000 164 Operating Instructions 11 2018 A5E03071515 AE ...