Object
No.
Byte
Bit
Data format Parameters
Value range
[encoding]
Incre‐
ment
3RW
50 / 52
1)
[D
3)
]
55 /
55‑F
2)
[D
3)
]
5
18
0
Bit2
Response to overload
thermal motor model
9)
[0 ... 1]
-
r
[0]
r/w
4)
[0]
[0] Turn off without restart
[1] Turn off with restart
232
4
Bit4
Response to faulty main
power
9)
[1 ... 2]
-
-
r/w
[1]
[1] Group error only at ON
command
[2] Warn
6
19
0
Bit4
Tripping class
[0 ... 15]
-
r
50: [0]
52: [3]
r/w
4)
[0]
[0] CLASS 10E
[1] CLASS 20E
[2] CLASS 30E
5), 6)
[3] CLASS 10A
[15] CLASS OFF
7
20
0
Unsigned8
Recovery time
9)
60 … 1 800 s
[2 … 60]
30 s
-
r/w
4)
[10]
10
24
0
Bit2
Response to overload
temperature sensor
9)
[0 ... 2]
-
r
[0]
r/w
4)
[0]
[0] Turn off without restart
[1] Turn off with restart
[2] Warn
5), 6)
9
2
Bit4
Temperature sensor
9)
[0 ... 2]
-
-
r/w
4)
[0]
[0] Deactivated
[1] Thermoclick
[2] PTC type A
140
33
2
Bit2
Response to overload
switching element
9)
[0 ... 1]
-
r
[0]
r/w
[0]
[0] Turn off without restart
[1] Turn off with restart
21
34
0
Bit4
Asymmetry limit error
9)
10 … 60 %
[2 … 12]
5 %
-
r/w
[6]
[0] Deactivated
47
45
0
Unsigned8
DC braking torque
20 … 100 %
[4 … 20]
5 %
-
r/w
8)
[10]
40
48
0
Unsigned8
Starting voltage
20 … 100 %
[4 … 20]
5 %
r
[6]
r/w
[6]
Appendix
A.4 Data sets
SIRIUS 3RW5 PROFINET communication modules
182
Equipment Manual, 05/2021, A5E35631297002A/RS-AD/004