Process image input (PII) and process image output (PIQ)
The following process images are transferred:
• Process image input with 16 bytes
• Process image output with 4 bytes
Note
The tables for the process images describe only the supported process data. Inputs and outputs
that are not listed are not assigned.
Process image input (PII)
Process data
Process image
3RW
50
1)
52
2)
55 /
55-F
3)
DI 0.0
Ready (automatic)
x
x
x
DI 0.1
Motor On
x
x
x
DI 0.2
Group error
x
x
x
DI 0.3
Group warning
x
x
x
DI 0.4
Input 1
x
x
x
DI 0.5
Input 2
-
-
x
DI 0.6
Input 3
-
-
x
DI 0.7
Input 4
-
-
x
DI 1.0
Motor current Iact-bit0
x
x
x
DI 1.1
Motor current Iact-bit1
x
x
x
DI 1.2
Motor current Iact-bit2
x
x
x
DI 1.3
Motor current Iact-bit3
x
x
x
DI 1.4
Motor current Iact-bit4
x
x
x
DI 1.5
Motor current Iact-bit5
x
x
x
DI 1.6
Local manual mode
x
x
x
DI 1.7
Ramp operation
x
x
x
DI 2.0
Motor CW
x
x
x
DI 2.1
Motor CCW
-
-
x
DI 2.4
Starting mode active
x
x
x
DI 2.5
Operation / bypass active
x
x
x
DI 2.6
Stopping mode active
x
x
x
DI 2.7
Test mode active
x
x
4)
x
DI 3.0
Motor overload protection – shutoff
x
x
x
DI 3.1
Temperature sensor overload
x
x
x
DI 3.2
Switching element overload
x
x
x
DI 3.3
Cooling time active
x
x
x
DI 3.4
Device error
x
x
x
DI 3.5
Automatic parameterization active
-
-
x