Byte
Data format Statistic data
Value range
Incre‐
ment
3RW
50 /
52
1)
55 /
55-F
2)
52
Unsigned32
Operating hours - motor current = 90 ... 119.9% x
Iemax
0 … 4 294 967 295 s 1 s
r
r
56
Unsigned32
Operating hours - motor current = 120 ... 1000% x
Iemax
0 … 4 294 967 295 s 1 s
r
r
62
Unsigned16
Number of switching element overload trips
0 … 65 535
1
r
r
64
Unsigned16
Number of bypass overload trips
0 … 65 535
1
r
r
72
Unsigned32
Number of electrical braking stops
0 … 4 294 967 295
1
-
r
76
Unsigned32
Number of starts output 1
0 … 4 294 967 295
1
-
r
80
Unsigned32
Number of starts output 2
0 … 4 294 967 295
1
-
r
84
Unsigned32
Number of starts output 3
0 … 4 294 967 295
1
-
r
88
Unsigned32
Number of starts output 4
0 … 4 294 967 295
1
-
r
128
Float32
Active energy import (total)
0 …
4 294 967 295 Wh
1 Wh
-
r
136
Float32
Active energy export (total)
0 …
4 294 967 295 Wh
1 Wh
-
r
144
Unsigned16
Last real starting time
0 … 1 000 s
0.1 s
-
r
146 ...
199
-
Reserved
-
-
-
-
1)
Supported by SIRIUS 3RW50 soft starter from firmware version V1.0 and 3RW52 from firmware version V2.0
2)
Supported by SIRIUS 3RW55 and 3RW55 Failsafe soft starters
A.4.5.6
Data set 96: Maximum pointer
Only read (r) access to the maximum pointer is possible.
Byte
Data format
Meaning
3RW
50
1)
52
2)
55 /
55-F
3)
0
Unsigned8
Coordination
x
x
x
2
Unsigned8
Slot number
x
x
x
4
Unsigned16
Length of data structure
x
x
x
6
Unsigned16
Start position
x
x
x
1)
Supported by SIRIUS 3RW50 soft starter
2)
Supported by SIRIUS 3RW52 soft starter
3)
Supported by SIRIUS soft starter 3RW55 and 3RW55 Failsafe
Byte
Data format Maximum pointer
Value range
Incre‐
ment
3RW
50 /
52
1)
55 /
55-F
2)
12
Unsigned8
Minimum phase current I L1 (%)
0 … 796.9 %
3.125 % r
r
13
Unsigned8
Phase current I L2 min (%)
0 … 796.9 %
3.125 % r
r
14
Unsigned8
Phase current I L3 min (%)
0 … 796.9 %
3.125 % r
r
Appendix
A.4 Data sets
SIRIUS 3RW5 PROFINET communication modules
Equipment Manual, 05/2021, A5E35631297002A/RS-AD/004