Assigning device parameters
5.3 Configuration settings of the device
Industrial Thin Client ITC1200, ITC1500, ITC1900, ITC2200
50
Operating Instructions, 04/2013, A5E03474888-02
5.3.5
Connections
5.3.5.1
Basics
Introduction
Users can connect from the Thin Client to different servers. Example:
●
RDP Server 1: Access to office planning documents
●
VNC Server 2: Access to Office spreadsheets
●
Sm@rtServer 3: Access to WinCC messages at the plant
●
SINUMERIK Server 4: Access to a SINUMERIK plant screen
●
Web Server 5: Access to web-based content, for example, of an S7 controller
(PROFINET) or Intranet/Internet using the integrated web browser.
Note
Web connection and web browser
You can configure a web connection, for example, the server address, in the Connection
settings (Page 54). You configure the web browser itself, for example, its proxy settings,
in the Application settings (Page 64).
You can establish up to 5 such client-server connections at the same time. These
connections are specified mainly by the following parameters:
●
Connection type, e.g., "Sm@rtServer" or "RDP"
●
IP address of the server
●
Port of the server
The Industrial Thin Client then displays the server screen as a full screen.
This section shows how you configure client-server connections. The connection settings
can be found in the configuration settings in the Start menu "Configuration > Connections".