Assigning device parameters
5.3 Configuration settings of the device
Industrial Thin Client ITC1200, ITC1500, ITC1900, ITC2200
Operating Instructions, 04/2013, A5E03474888-02
51
Special features with SINUMERIK
Note
The SINUMERIK connection is configured automatically through the SINUMERIK system
network and therefore does not need any connection settings or a connection password.
Note
PROFINET basic functions
The SINUMERIK connection supports only the PROFINET basic services. During a
SINUMERIK connection, a new IP address is assigned to the device with the following effect:
Any active RDP connection is terminated.
Remote maintenance of the device is no longer possible.
When the SINUMERIK connection is closed, the original IP address is restored.
Screen can no longer be operated
The screen can no longer be operated when you start a second SINUMERIK connection.
Close the active SINUMERIK connection before you start a new SINUMERIK connection.
Screen display
The SINUMERIK connection is displayed full-screen on the Industrial Thin Client. In the
process, the server adapts its screen resolution to the screen resolution of the client that has
the operating rights.
All other connected clients also display the server screen:
●
If the clients without operating rights have a lower screen resolution than the server, the
clients scale down the server screen that is too large and display it as a full screen.
●
If the clients without operating rights have the same or higher screen resolution, the
clients display the server screen with reduced size in the center and in the original
resolution.
Displaying client-server connections in the taskbar
The "Display connection (favorites)" option is enabled by default so that the client-server
connection appears in the start bar (under "Favorites") and can be started from there. The
favorites contain a maximum of 10 client-server connections.
It makes sense to disable the "Display connection (favorites)" option in the following
situations:
●
A server that is regularly used from a client is undergoing maintenance and is therefore
not connected.
●
A second, redundant server is being set up, for the case that the first server fails.
●
A client-server connection that is started automatically as a startup connection does not
need to be started from the taskbar.