Commissioning and Diagnostics
6-49
ET 200S Distributed I/O System
EWA-4NEB 780602402-12
Interrupts
If the configuration was done with STEP 7, the interrupt data will be evaluated and
sent to the relevant organization function blocks (OBs).
The interrupt section for the ET 200S is structured as follows:
Byte x
7 6
0
5 4 3 2 1
Code for device-specific diagnosis
Length of the interrupt section incl. byte x (= max. 48 bytes)
0
1
0 0 0
0
0
0
Byte x+1
7 6
0
5 4 3 2 1
Interrupt type
0000001
B
: Diagnostic interrupt
0000010
B
: Process interrupt
0000011
B
: Remove interrupt
0000100
B
: Insertion interrupt
0
Byte x+3
7 6
0
5 4 3 2 1
0
Interrupt sequence
number (1 to 31)
Diagnostic interrupt:
01
B
: at least one error is
pending
10
B
: going error
11
B
: Reserved
Process interrupt:
00
B
Remove interrupt:
00
B
for
IM151-1 HIGH FEATURE
01
B
for
IM151-1 STANDARD and
IM151-1 FO STANDARD
Insertion interrupt:
10
B:
correct module
inserted
11
B:
wrong module
inserted
Byte x+2
7 6
0
5 4 3 2 1
00: IM151-1 (STANDARD, HIGH FEATURE) sends interrupt
01 to 63: Slot of the module returning the interrupt
Slot numbers
:
Byte x+4 to...
... byte x+43
... Byte x+7
... Byte x+8...
Diagnostic data
(contents of data
record 1)
Process
interrupt data
•
Remove/insertion interrupt
data for IM151-1 HIGH
FEATURE
•
not with
IM151-1 STANDARD and
IM151-1 FO STANDARD
Figure 6-27
Structure of the interrupt status of the interrupt section
Содержание SIMATIC ET 200S
Страница 42: ...Product Overview 1 16 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 64: ...Brief Instructions on Commissioning ET 200S 2 22 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 112: ...Configuration Options 3 48 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 232: ...Commissioning and Diagnostics 6 72 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 244: ...General Technical Specifications 7 12 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 274: ...Interface Modules 8 30 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 538: ...4 IQ SENSE 13 18 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 564: ...Address Space of the Input and Outputs of the ET 200S C 4 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 574: ...Response Times D 10 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 580: ...Special Measures for Interference Free Operation F 4 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 600: ...Product Information on the Use of subassemblies modules in a Zone 2 Hazardous Area 2 A5E00352937 02 ...