Diagnostics
12.3 Loop detection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
921
Syntax
Call the command without parameters:
loopd reaction remote
Result
"disable" is activated for the
loopd reaction remote
function.
"disable" is the default after enabling loop detection.
Further notes
You enable the "no action" reaction with the
no loopd reaction remote
command.
You can display the status of this function and other information with the
show loopd
command.
12.3.3.7
no loopd reaction remote
Description
With this command, you enable the "no action" reaction for a remote loop. If a remote loop is
detected, this has no effect on the port.
Requirement
●
loopd is enabled
●
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no loopd reaction remote
Result
"no action" is activated for the
loop reaction remote
function.
"disable" is the default after enabling loop detection.
Further notes
You enable the "disable" setting with the
loopd reaction remote
command.
You can display the status of this function and other information with the
show loopd
command.