Diagnostics
12.1 Event and fault handling
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
885
Result
The logging function is disabled on the console.
Further notes
You enable the setting with the
logging console
command.
As default the function is "disabled".
12.1.3
The "show" commands
This section describes commands with which you display various settings.
12.1.3.1
show events config
Description
This command shows the current configuration for forwarding the messages of the various
event types.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
or
cli#
Syntax
Call the command without parameters:
show events config
Result
The current configuration of the events display is displayed.
12.1.3.2
show events severity
Description
This command shows the degree of severity of an event ("Info", "Warning" or "Critical")
starting at which a notification (sending of an e-mail, entry in the Syslog table, entry in the
Syslog file) is generated.