Security and authentication
11.1 User management
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
815
11.1.4.9
no user-group
Description
With this command, you delete the link between a group and a role.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no user-group <user-group-name>
The parameter has the following meaning:
Parameter
Description
Range of values / note
user-group-name
Group name
Enter the name of a group.
Result
The link is deleted.
Further notes
You link a group with a role with the
user-group
command.
You show the created links with the
show user-groups
command.
11.1.4.10
username
Description
With this command, you change the password of the factory set default user "
admin
".
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#