Network protocols
7.9 SMTP Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
417
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
sender mail-address <mail-address>
The parameter has the following meaning:
Parameter
Description
Range of values / note
mail-address
Email name of the sender
max. 100 characters
Result
The e-mail name of the sender is configured.
Further notes
You reset the e-mail name of the sender with the
no sender mail-address
.
You display the setting with the
show events sender email
command.
7.9.2.4
no sender mail-address
Description
With this command, you reset the e-mail name of the sender.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call the command without parameters: