Network structures
6.4 Passive Listening
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
279
Result
The MST region is assigned a revision number.
Further notes
You delete a revision number with the
no revision
command.
You display this setting and other information with the
show spanning tree mst
configuration
command.
6.3.6.6
no revision
Description
With this command, you reset the revision number of the MST region to the default value.
The default value is 0.
Requirement
You are in the MSTP Configuration mode.
The command prompt is as follows:
cli(config-mst)#
Syntax
Call the command without parameters:
no revision
Result
The revision number of the MST region is reset to the default value.
Further notes
You assign a revision number to the MST region with the
revision
command.
You display this setting and other information with the
show spanning tree mst
configuration
command.