Load control
10.1 Rate control
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
780
Configuration Manual, 06/2016, C79000-G8976-C252-11
10.1.2.5
storm-control level
Description
With this command, you configure the value for the storm control function in Kbps.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
storm-control level <rate-value>
The parameters have the following meaning:
Parameter
Description
Range of values / note
rate-value
Value for the in data rate in Kbps
The value range depends on the
port speed. The entry is rounded
down to the next valid value. If
small values are entered, the
value is rounded up to the next
valid value.
Default:
The data rate is set to 0. The
incoming data stream is not lim-
ited.
Result
The value for the storm control function is configured.
Further notes
You can reset the setting to the default with the
no storm-control level
command.
10.1.2.6
no storm-control level
Description
With this command, you reset the value for the storm control function to the default value.
The default value for the storm control level is 0 Kbps. The incoming data stream is not
limited.