Configuration
3.2 Load and Save
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
111
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
or
cli#
Syntax
Call the command without parameters:
show loadsave tftp
Result
The current configuration of the TFTP server for Load&Save is displayed.
3.2.2
load tftp
Firmware
The firmware is signed and encrypted. This ensures that only firmware created by Siemens
can be downloaded to the device.
Description
With this command, you load the files from a TFTP server.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
or
cli#
Syntax
Call up the command with the following parameters:
load tftp {ipv4 <ucast_addr> | fqdn-name <FQDN> | ipv6 <ip6_addr>} [port <tcp port
(1-65535)>] file <filename> filetype <filetype>
The parameters have the following meaning:
Parameter
Description
Range of values / note
ipv4
Keyword for an IPv4 address
ucast_addr
IPv4 unicast address of the TFTP
server
Enter a valid unicast IPv4 ad-
dress.