Functional description and configuration using Web based Management
7.7 The Agent menu
SCALANCE X204RNA SCALANCE X204RNA EEC (PRP)
Operating Instructions, , C79000-G8976-C294-03
81
Figure 7-28 Agent Event Configuration with the SCALANCE X204 RNA
You can configure the reaction of the SCALANCE X-200RNA to the following events:
Cold / Warm Start
The SCALANCE X-200RNA was turned on or restarted by the user.
Link Change
A port has failed or data traffic is being handled again over a port that had previously failed.
Authentication Failure
There was an SNMP access with a bad password or inadequate access rights.
Power Error (SCALANCE X204RNA only)
This event occurs only when the power supply line 1 and line 2 are monitored. It indicates
that there was a change to line 1 or line 2.
Fault State Change
The fault status has changed. The fault status can relate to the activated port monitoring, the
response of the signaling contact or the power supply monitoring.
Redundancy Event
There are two situations that are signaled as a redundancy error.