Functional description and configuration using Web based Management
7.7 The Agent menu
SCALANCE X204RNA SCALANCE X204RNA EEC (PRP)
86
Operating Instructions, , C79000-G8976-C294-03
7.7.12
Agent Time Configuration
Time-of-day synchronization in the network
SNTP (Simple Network Time Protocol) is used for synchronizing the time in the network. The
appropriate frames are sent by an SNTP server in the network. A SCALANCE X-200RNA
logs on as client with this server as recipient of time-of-day frames.
Figure 7-32 Agent Time Configuration
System Time
This box displays the current system time. If no time-of-day synchronization was possible,
the box displays "Date/time not set".
You can also set the date and time manually, the required input format is MM/DD/YYYY
HH:MM:SS. In this case, the text box displays the data and time along with the suffix (m). If
the system time was set as a result of synchronization with a server, the suffix is (p).
Time Synchronization
This box is read-only and shows when the last time-of-day synchronization took place.
SNTP Mode
The protocol type used is displayed here: