![Siemens SCALANCE X204RNA EEC Скачать руководство пользователя страница 73](http://html.mh-extra.com/html/siemens/scalance-x204rna-eec/scalance-x204rna-eec_operating-instructions-manual_383821073.webp)
Functional description and configuration using Web based Management
7.7 The Agent menu
SCALANCE X204RNA SCALANCE X204RNA EEC (PRP)
Operating Instructions, , C79000-G8976-C294-03
73
7.7.4
SNMP Trap Configuration
SNMP traps for alarm events
If an alarm event occurs, a SCALANCE X-200RNA can send traps (alarm frames) to up to
10 different (network management) stations at the same time. Traps are only sent when
events as specified in the Agent Event Configuration menu occur (see Section "Agent Event
Configuration" (Page 79)).
Note
Traps are sent only when the "Traps" option was selected in "SNMP Configuration".
Figure 7-21 SNMPv1 Trap Configuration
IP Address
Here, you enter the addresses of the stations to which a SCALANCE X-200RNA will send
traps.
Enable Trap
Click on the check box next to the IP addresses to enable the sending of traps to the
corresponding stations.