Functional description and configuration using Web based Management
7.7 The Agent menu
SCALANCE X204RNA SCALANCE X204RNA EEC (PRP)
Operating Instructions, , C79000-G8976-C294-03
87
●
Poll
If you choose this protocol type, you have to define further settings:
Time zone offset, Time server, Init poll interval, Poll interval.
SNTP Server IP Address
Here, you enter the IP address of the SNTP server whose frames will be used by a
SCALANCE X-200RNA to synchronize the time of day.
SNTP Server Port
Here, enter the port over which the SNTP server is available.
Time Zone
Select the time zone for the location of the SCALANCE X-200RNA because the SNTP
server always sends UTC time. This time is then recalculated and displayed as the local time
based on the time zone. There is no standard/daylight-saving time switchover on the
SCALANCE X-200RNA.
Init poll interval
Here, you can enter the interval at which a SCALANCE X-200RNA repeats the initial poll for
the system time if this was not successful the first time.
Poll interval
Once the system time has been adopted the first time from the time server, it is updated
cyclically with renewed polls to the time server. Here, you specify how often the updates take
place.