Parameters
password
Specifies the password used for authentication
Examples
The following example sets an authentication password:
WLC.siemens.com
:ip:ospf:ospfinterface:top1# authkey hello123
authtype
Use the
authtype
command to indicate whether the authentication will require a password or not.
authtype ( none | password )
Parameters
none
Indicates that no password is required
password
Indicates that authentication will require a password
Examples
The following example configures authentication to require a password:
WLC.siemens.com
:ip:ospf:ospfinterface:top1# authtype password
deadinterval
Use the
deadinterval
command to set the amount of time the OSPF protocol will wait for a response
before assuming peer devices are unreachable.
deadinterval 1-65535
Parameters
1-65535
Specifies the time interval (in seconds) the OSPF protocol will wait for a response
Examples
The following example sets the time to wait for a packet response to 300 seconds:
WLC.siemens.com
:ip:ospf:ospfinterface:top1# deadinterval 300
hellointerval
Use the
hellointerval
command to specify the time interval between the transmission of OSPF Hello
packets to devices on the network.
hellointerval 1-65535
ip Commands