8.4.12
RAM error (RAM ERROR)
Error
Meaning
INTEGRITY
ERROR
Wrong integrity check on the RAM
8.4.13
Sensor configuration errors (SENSOR CONFIGURATION ERROR)
Error occurred on the sensors during the configuration process or at the system power
up. At least one of the connected sensors did not get the correct configuration.
As details, the list of sensors not configured is reported.
8.5
ERROR events (sensor)
8.5.1
Introduction
A diagnostic error is logged every time the periodic diagnostic functions detect a coming
or going fault on the safeRS3 Sensor.
8.5.2
Misconfiguration error (MISCONFIGURATION ERROR)
The misconfiguration error occurs when the sensor does not have a valid configuration
or it has received an invalid configuration from the control.
8.5.3
Status error and fault (STATUS ERROR/FAULT ERROR)
The status error occurs when the sensor is in an internal invalid status or it has reached
an internal fault condition.
8.5.4
Protocol error (PROTOCOL ERROR)
The protocol error occurs when the sensor receives commands with an unknown
format.
8.5.5
Sensor voltage errors (POWER ERROR)
Error
Meaning
Sensor voltage
UNDERVOLTAGE
Undervoltage error for the indicated voltage
Sensor voltage
OVERVOLTAGE
Overvoltage error for the indicated voltage
The following table describes the sensor voltage:
Screen printing
Description
VIN
Power supply voltage (+12 V DC)
V3.3
Internal chip power supply voltage
V1.2
Micro-controller power supply voltage
V1.8
Internal chip power supply voltage (1.8 V)
V1
Internal chip power supply voltage (1 V)