8 MAINTENANCE AND TROUBLESHOOTING
Event
Type
Detection exit
INFO
Dynamic configuration in use INFO
Muting status
INFO
Fieldbus connection
INFO
Modbus connection
INFO
Session authentication
INFO
Validation
INFO
Log download
INFO
For further information about the events, see
and
ERROR events (control) on page 90
.
8.2.10
Verbosity level
There are six verbosity levels for the log. The verbosity can be set during the
configuration of the system via the safeRS3 Designer application (
Settings
>
Activity
History
>
Log verbosity level
).
Depending on the selected verbosity level, the events are logged in accordance to the
following table:
Event
Level 0
(default)
Level 1
Level 2
Level 3
Level 4
Level 5
Diagnostic errors
x
x
x
x
x
x
System Boot
x
x
x
x
x
x
System configuration
x
x
x
x
x
x
Factory reset
x
x
x
x
x
x
Stop signal
x
x
x
x
x
x
Restart signal
x
x
x
x
x
x
Detection access
-
See
Verbosity level for detection access and exit
Detection exit
-
See
Verbosity level for detection access and exit
Dynamic configuration in
use
-
-
-
-
x
x
Muting status
-
-
-
-
-
x
8.2.11
Verbosity level for detection access and exit events
Depending on the selected verbosity level, the detection access and exit events are
logged as follows:
l
LEVEL 0: no detection info is logged
l
LEVEL 1: the events are logged at control level and the additional information are the
detection distance (in mm) and the detection angle (in °) in detection access.
Format:
CONTROL Detection access (distance mm/azimuth°)