108
O P E R A T I N G I N S T R U C T I O N S | safeRS3
8027489/2022-03-01 | SICK
Subject to change without notice
9 TECHNICAL REFERENCES
9.3.5
Connection of the muting input and output (one group of sensors)
Note
: the cables used for wiring the digital inputs must have a maximum length of 30 m
(98.4 ft).
Digital I/O settings (through the safeRS3 Designer application)
Digital input #1 Not configured
Digital input #2 Muting group 1
Digital output #1 Not configured
Digital output #2 Not configured
Digital output #3 Muting enable feedback signal
Digital output #4 Not configured