Electrical installation
32
© SICK AG · Germany · All rights reserved · Subject to change without
notice
8016535/1D2F/2022-11-14
Operating instructions
NAV310 Laser positioning sensor
Chapter
5
“Power” connection M12 × 5, plug, A coded
“Ethernet” connection M12 × 4, socket, D coded
“RS232” connection M12 × 8, plug, A coded
5.3
Preparing the electrical installation
5.3.1
Supply voltage
DC 24 V ±15
% as per IEC 60
364-4-41 (pay attention to permitted cable lengths in
)
The NAV310 draws the following power:
•
on switching on without switching outputs wired maximum 36 W
•
in operation typically 12 W, plus a maximum of 12 W with switching output wired
The supply of power/the external power supply for the supply of power must be able to
provide at least 40 W continuous power, if the switching output is wired at least 48 W
continuous power.
Pin
Signal
Function
1
V
S
Supply voltage NAV310
2
V
S
Supply voltage NAV310
3
GND
Ground
4
OUT 24 V
Digital output 1
5
GND
Ground
Tab. 8:
Pin assignment of the “Power” connection on the NAV310
4
2
3
5
1
Pin
Signal
Function
1
Ethe
Ethernet interface
2
Ethe
Ethernet interface
3
Ethernet_TX–
Ethernet interface
4
Ethernet_RX–
Ethernet interface
Tab. 9:
Pin assignment of the “Ethernet” connection on the NAV310
1
2
4
3
Pin
Signal
Function
1
RxD
Serial RS232 host interface (receiver)
2
TxD
Serial RS232 host interface (sender)
3
–
Do not use
4
–
Do not use
5
GND RS-232
Ground RS-232
6
OUT 24 V
Do not use
7
OUT 24 V
Do not use
8
OUT 24 V
Do not use
Tab. 10: Pin assignment of the “RS232” connection on the NAV310
2
1
8
7
6
5
4
3