Operating instructions
NAV310
Commissioning and configuration
8016535/1D2F/2022-11-14
© SICK AG · Germany · All rights reserved · Subject to change without notice
43
Chapter
6
6.5
Connection and test measurement
Use the graphic scan view in SOPAS ET to verify the generated measured values and to ver-
ify the measurement area online.
1. Select NAV310, M
ONITOR
, S
CAN
D
ISPLAY
in the project tree.
2. To start the measurement, click the P
LAY
button.
3. Compare the measurement line with the required result.
Important
– The S
CAN
V
IEW
in the M
ONITOR
is dependent on the available computing power of the
PC and is
not
output in real-time. For this reason not all measured values are dis-
played. The same limitation also applies when saving measured values displayed in
a file.
4. After completing the test measurement successfully, save the configuration perma-
nently to the NAV310: Menu NAV310, P
ARAMETER
, S
AVE
PERMANENT
.