Data sheet NAV310
Characteristic
NAV310
Output of measured values
Measuring range
1)
2)
1) Condition: laser spot completely on the target, warm-up time min. 30 min.
0.5 … 35 m, at 10 % remission
0.5 … 120 m, at 90 % remission
maximum 0.5 … 250 m
Usable scan angle
3)
max. 360°, field evaluation 300
°
Angular resolution
(step width)
0.125°; 0.1875°; 0.25°; 0.375°; 0.5°; 0.75°; 1° (Interlaced:
0.0625°)
Scanning frequency
5-20 Hz, rotational direction CW
Measurement resolution
3.9 mm up to 250 m in USP interface
4 mm up to 250 m
Systematic error
at 25 °C
+/- 10 mm (25 °C) with reflective tape up to 50 m
+/- 15 mm (25 °C) at 90 % remission
+/- 25 mm (25 °C) at 20 % remission
Statistical error distance
(1 sigma)
25 mm at 20 … 90 % remission
15 mm with reflective tape
Temperature drift typ.
typ.
±
0,6 mm/K
General data
Beam divergence
5.0 mrad
Laser diode (wavelength)
Infrared light (
λ
= 905 nm)
Pulse frequency
max. 14.4 kHz (max. 12 kHz above 360°)
Laser class of the device
Class 1 as per EN/IEC 60825-1:2014, eye safe, 21 CFR
1040.10 and 1040.11 expect for deciations pursuant to Laser
Notice No. 50, dated June 24, 2007.
RS-232 data interface
19,200; 38,400; 57,600; default: 115,200 Bd
Data format
Variable; default: 8 data bits, 1 stop bit, no parity
Output signal switching device 100 MBit/s, TCP/IP
Ethernet Protokolle
CoLaA-/B (Port: 2112)
Serielle Protokolle
CoLa-A(Port: 2111), USP (Port: 49152)
Switch outputs
1 × (OUT1 for synchronisation);
Semiconductor output, active high,
maximum output current 0.5 A at DC 24 V
operating voltage
DC 24 V
±
15%/IEC 60 364-4-41 (VDE 0100 part 410)
Housing
According to EN 61 000-6-2 (2005-08)/EN 61 000-6-4 (2007-01)
Housing
Aluminium die-cast
Enclosure rating
III according to EN 61 140 (2002-03)
International protection rating IP 65 according to EN 60 529 (1991-10); A1 (2002-02)
Vibration test
According to IEC 60 068-2-6, table 2c (frequency range
10 … 150 Hz, amplitude 0,35 mm or 5 g)
weight
Approx. 2.4 kg
Ambient operating tempera-
ture/storage temperature
0 … +50
°
C/–20 … +80
°
C
Max. relative air humidity
5 … 85 %, non-condensing
Tab. 16: Data sheet NAV310