Commissioning and configuration
38
© SICK AG · Germany · All rights reserved · Subject to change without
notice
8016535/1D2F/2022-11-14
Operating instructions
NAV310 Laser positioning sensor
Chapter
6
6. Confirm the settings in the S
CAN
A
SSISTANT
dialog box with OK.
The S
CAN
A
SSISTANT
dialog box is closed.
6.3.4
Configuring the Ethernet connection
The factory setting for the Ethernet interface of the
NAV310
is as follows:
– IP address: 192.168.1.10
– subnet mask: 255.255.255.0
– TCP/ IP port for SOPAS ET: 2112
– CoLa- A (ASCII) and CoLa-B (binary) selectable
Configuring with fixed IP address
Important
Deactivate all programs on your PC/notebook that access Ethernet or TCP/IP.
1. From the START MENU, click CONTROL PANEL and choose NETWORK CONNECTIONS.
2. Right-click the LOCAL AREA CONNECTION icon, and then choose PROPERTIES.
3. On the GENERAL tab, highlight INTERNET PROTOCOL (TCP/IP), and then click PROPER-
TIES
4. Select USE THE FOLLOWING IP ADDRESS, and enter the following IP address:
192.168.1. x (e.g. 1)
5. Confirm with OK