Operating Instructions
Chapter
5
Flexi Soft Gateways
8012664/XB29/2013-06-11
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
45
Subject to change without notice
Ethernet gateways
Configuration via Flexi Soft Designer tool
In order to configure the
Gateway writes to Address/Port (Auto update)
mode of the
gateway via the Flexi Soft Designer tool, perform the following steps:
Open the Flexi Soft Designer and load the hardware configuration including the
gateway.
Click on the
Gateways
button above the main window and select the desired gateway or
double click the desired gateway in the hardware configuration view to open the
gateway configuration dialog.
Click on
TCP/IP configuration
on the left hand menu. The following dialog appears:
Activate the
Connect to
radio button.
Enter the
IP address
and the
Port
number the gateway shall write to.
Select the update mode:
Enable COS update
or
Enable auto update and COS
.
If you have selected
Enable auto update and COS
, select the
Update rate
in ms.
Select which data sets shall be updated: Check the
Update data set n
checkbox.
Fig. 18: TCP/IP configuration
for auto update