Fieldbus gateways
SDO 100D: Life time factor
SDO 100D contains the life time factor (SINT). See SDO 100C.
The life time factor must be either = 0 (disabled) or
O
1.5.
SDO 1016: Consumer heartbeat time
The gateway is configured as a heartbeat consumer if SDO 1016 contains a value higher
than 0 for the consumer heartbeat time. The consumer heartbeat time is defined in ms.
The NMT master must send at least one node guarding message to the slave within this
time. If the consumer heartbeat time is exceeded (life-guarding error), the gateway ge-
nerates a cable break error and sets all process data coming from the network to 0; the
NS LED will start flashing
Red.
SDO 1017: Producer heartbeat time
The gateway can also function as a heartbeat producer, i.e. send a heartbeat signal. This
allows another device to detect whether the heartbeat producer (i.e. the gateway) is still
working correctly.
The producer heartbeat time is defined in ms. For internal processing it is rounded to the
next higher multiple of 4. If the heartbeat time is set to 0, the heartbeat signal is
deactivated.
The heartbeat signal consists of a cyclic CAN message with the identifier 700h + device
address.
It is not possible to use heartbeat signals and life guarding messages at the same time
because both functions use the same CAN identifier.
See also section 6.2.11 “Guarding protocols” on page 153.
SDO 1018: Identity record
This SDO contains basic information about the gateway.
Subindex Mapping
Format
Description
1
Vendor ID
UDINT
Unique identification of the
manufacturer (e.g. SICK)
2
Product code
UDINT
Device variant
3
Revision number
UDINT
Software version of the device
4
Serial number
UDINT
Serial number of the device
SDO 1027: Module list
The module list contains the module type and the module ID of all Flexi Soft modules in
the system.
Subindex Module
Format
1
Main module (FX3-CPU0, -CPU1 or -CPU2)
SINT
2…13
Extension modules (XTIO, XTDI or MOCx)
SINT
14, 15
Gateways SINT
You can find the module types and module IDs in Tab. 105. The return value for free
module slots is 0.
Note
Note
Tab. 120: SDO 1018
contents
Tab. 121: SDO 1027
contents