30
8020216/19YN/V3-0/2020-12| SICK
O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER SP100 Ex-3K
Subject to change without notice
3
PRODUCT DESCRIPTION
MCU type code
A type code identifies the special version of the control unit:
MCU control unit, type code (extract):
MCU - N W O D N 0 0 0 0 0 N N N E
Purge gas supply
- N:
Not present
Voltage supply
- W:
90…250 V AC
- 2
24 V DC
Enclosure variants
- O:
Wall enclosure, compact, SICK orange, stainless steel
Display module
- D:
Present
Other options
- N:
Not present
Analog input module
(0/4...20 mA; 2 inputs per module)
- 0
Not present
Analog output module
(0/4...20 mA; 2 outputs per module)
- 0
Not present
Digital input module
(4 inputs per module)
- 0
Not present
Digital output module W
(48 V DC 5 A; 2 changeover contacts per module)
- 0
Not present
Digital output module W
(48 V DC 0.5 A; 2 changeover contacts per module)
- 0
Not present
Interface module
- N:
Not present
- M:
Interface module, RS 485 (Modbus® ASCII/RTU)
- J:
Interface module, Ethernet (Modbus® TCP)
- V:
Ethernet Interface module (CoLa-B)
Special features
- N:
None
- S: Special solution
EX certification
- N:
None
Software
- E:
Emission