PRODUCT DESCRIPTION
MCUDH Ex-3K type code
A type code identifies the special version of the control unit:
MCUDH Ex-3K (extract) control unit type code:
MCUDH -N 2 Y D N 0 0 0 0 0 M N 0 E
Purge gas supply
- N:
Not present
Voltage supply
- S:
90…250 V EX
- 2
24 V DC
Enclosure variants
- Y:
Wall enclosure, middle, 300×300×220, stainless steel
- Z:
Ex-d enclosure, aluminium, coated
Display module
- D:
Present
Other options
- N:
Not present
Analog input module
(0/4...20 mA; 2 inputs per module)
- 0
Not present
Analog output module
(0/4...20 mA; 2 outputs per module)
- 0
Not present
Digital input module
(4 inputs per module)
- 0
Not present
Digital output module W
(48 V DC 5 A; 2 changeover contacts per module)
- 0
Not present
Digital output module W
(48 V DC 0.5 A; 2 changeover contacts per module)
- 0
Not present
Interface module
- N:
Not present
- M:
RS485 Interface module for transmission
from Modbus® ASCII/RTU o. CoLa-B
Special features
- N:
None
- S: Special solution
EX certification
- O:
ATEX zone 2/22:
Software
- E:
Emission