O P E R AT I N G I N S T R U C T I O N S | Bulkscan®
8014829/ZV98/2018-05-07 | S I C K
Subject to change without notice
1 0 8
APPENDIX
13.1.12
Reference measurement (compensation function)
Permissible commands:
sRN, sEN
Variable name
Description
Variable type Value range
Unit
ccStatus
Status of the reference mea-
surement
uint_8
0: Deactivated
1: Active
ccMeasVolume1
Measured volume
(reference measurement 1
to 10)
float_32
m³
ccMeasVolume2
ccMeasVolume3
ccMeasVolume4
ccMeasVolume5
ccMeasVolume6
ccMeasVolume7
ccMeasVolume8
ccMeasVolume9
ccMeasVolume10
ccMeasArea1
ccMeasArea2
ccMeasArea3
ccMeasArea4
ccMeasArea5
ccMeasArea6
ccMeasArea7
ccMeasArea8
ccMeasArea9
ccMeasArea10
Measured area (reference
measurement 1 to 10)
float_32
m
2
ccRefArea1
ccRefArea2
ccRefArea3
ccRefArea4
ccRefArea5
ccRefArea6
ccRefArea7
ccRefArea8
ccRefArea9
ccRefArea10
Reference area (reference
measurement 1 to 10)
float_32
m
2
Permissible commands:
sRN, sWN
Variable name
Description
Variable type Value range
Unit
ccRefVolume1
ccRefVolume2
ccRefVolume3
ccRefVolume4
ccRefVolume5
ccRefVolume6
ccRefVolume7
ccRefVolume8
ccRefVolume9
ccRefVolume10
Reference volume
(reference measurement 1
to 10)
float_32
≥ 0
m³
ccCoeff1
Quadratic coefficient of the
compensation function
float_32
ccCoeff2
Linear coefficient of the
compensation function
float_32