O P E R AT I N G I N S T R U C T I O N S | Bulkscan®
8014829/ZV98/2018-05-07| S I C K
Subject to change without notice
4 1
MOUNTING
5.3.9
Mounting of Bulkscan® LMS111 with mounting kit 2 or 3
With the aid of mounting kits 2 and 3 (only in conjunction with mounting kit 1a or 1b)
you can align the Bulkscan® LMS111 in two planes. The maximum adjustment angle is
±11° in both planes.
Mounting kit 1a
Mounting kit 2
Mounting kit 3
Threaded holes M4
Centring pin
Fig. 22: Mounting with mounting kit 2 (part no. 2039302) and kit 3 (part no.
2039303)
1. Mount mounting kit 1a or 1b to the Bulkscan® LMS111.
2. Mount the mounting kit 3 on the mounting surface.
3. Fit the centring pin (4 mm) in the central hole on mounting bracket 3.
4. Fit mounting kit 2 to mounting kit 3 and mount it using two fixing screws M4 × 10.
5. Then mount the Bulkscan® LMS111 on mounting kit 2 with the aid of the threaded
holes in mounting kit 1a.
6. Adjust the Bulkscan® LMS111 longitudinally and transversely and then tighten the
six fixing screws on the mounting kits.
During mounting, please observe the dimensional drawings (see "11.4.6 Dimensional
drawing mounting kits (only for Bulkscan® LMS111)“ on page 92).
5.3.10
Mounting of Bulkscan® LM511 with weather protection hood
To protect the Bulkscan® LMS511 from glare, precipitation and direct sunlight when
used outside the weather protection hood (part no. 2063050) is available.
You will find detailed dimensions in section „11.4.7 Dimensional drawing weather pro
tection hood for Bulkscan® LMS511“