O P E R AT I N G I N S T R U C T I O N S | Bulkscan®
8014829/ZV98/2018-05-07| S I C K
Subject to change without notice
8 3
TECHNICAL DATA
Supply voltage
Sensor
Heating
10.8 V
19.2 V
24 V
24 V
30.0 V
28.8 V
Permissible residual ripple
±5%
Switch on current
2 A
Operating current at 24 V DC
Sensor
Heating
0.33 A
1.8 A
0.4 A
2.6 A
Power consumption
Sensor
Heating
8 W
35 W
10 W
45 W
Digital inputs
Input resistance for HIGH
Voltage for HIGH
Voltage for LOW
Input capacity
Static input current
11 V
-30 V
6 mA
2 kΩ
24 V
0 V
15 nF
12 mA
30 V
5 V
15 mA
Encoder inputs
Input resistance for HIGH
Voltage for HIGH
Voltage for LOW
Input capacity
Static input current
Duty cycle (Ti/T)
Input frequency
Current load
11 V
-30 V
6 mA
2 kΩ
24 V
0 V
1 nF
15 mA
0,5
50 mA
30 V
5 V
20 mA
100 kHz
100 mA
Digital outputs
Voltage drop load
Maximum switching current
Current limiting (after 5 ms at 25 °C)
Power-up delay
Power-down time
100 mA
Negligible
2 V
0.8 ms
140 mA
200 mA
2 ms
Mechanical data
Housing color
RAL 7032 (gray)
Enclosure rating
IP67 (as per EN 60529 (1991-10); A1 (2002-02))
Protection class
III
Weight
1.1 kg
Dimensions
Width 102 mm × Depth 106 mm × Height 162
mm
Ambient data
EMC test
As per EN 61000-6-2 (2005-08), EN 61000-6-3
(2007-01)/A1 (2011-03)
Vibration resistance
Frequency range
Amplitude
10 Hz
5 g RMS
150 Hz
Shock resistance
Single shock
Continuous shock
IEC 60068-2-27
15 g, 11 ms
10 g, 16 ms
Operating temperature range
–30 °C
+50 °C