6.3.4
Input circuits IN1 and IN2 on Bulkscan® LMS511
Fig. 38: Input circuits IN1 and IN2
6.3.5
Connecting the outputs to a PLC on Bulkscan® LMS511
+
24 V EXT
OUT1, OUT2
1
4
3
Bulkscan® LMS511
PLC
2
_
Fig. 39: Connecting the outputs to a PLC (active LOW)
24 V EXT
OUT3 … OUT6
GND EXT
PLC
Bulkscan® LMS511
Fig. 40: Connecting the outputs to a PLC (active HIGH)
IN1 or IN2
GND EXT