TECHNICAL DATA
Storage temperature range
–30 °C
+70 °C (max. 24 h)
Ambient light immunity
40.000 lx
Tab. 23: Bulkscan® LMS111 data sheet
11.3
Analog module BAM100 data sheet
Electric
Minimum
Typical
Maximum
Power supply
20.4 V DC
24 V DC
28.8 V DC
Current consumption
max. 320 mA
Inrush current
2,5 x current consuption
Recommended fuse
<= 10 A
Power contacts
24 VDC max /
10 A max.
Isolation
500 V
Connection Bulkscan®
1 x RJ45
Transfer rate
10/100 Mbaud
Cable length between Bulkscan® and
BAM100
100 m max.
Analog input
4 x 4 mA … 20 mA
Internal resistance
< 85 Ohm
Resolution
12 Bit
Measurement error
<+-0,3% of final value
Surge voltage resistance
30 V DC
Total response time Bulkscan® and
BAM100
500 ms
Analog output
4 x 4 mA … 20 mA
Load
< 350 Ohm (short-circuit protected)
Resolution
12 Bit
Measurement error
<+-0,1% of final value
EMC
EN 61000-6-2/EN 61000-6-4
Connection technology
Wiring
Spring force tegnology Cage Clamp
Cross-sectional area
0,08 mm² … 2,5 mm², wire massive / solid,
AWG28-14
Stripping length
8 mm … 9 mm
Mechanical
Asembly
on 35 mm mounting rail according to EN 50022
Material housing
Polycarbonat
Dimensions (WxHxD)
86 mm x 100 mm x 68 mm
Weight
250 g
Encloser rate
IP20
Installation position
flexible
Vibration/ shock resistance
acc. EN 60068-2-6/EN 60068-2-27