O P E R AT I N G I N S T R U C T I O N S | Bulkscan®
8014829/ZV98/2018-05-07 | S I C K
Subject to change without notice
1 0 6
APPENDIX
Variable name
Description
Variable
type
Value range Unit
BsConveyorWarningRight
Right conveyor belt edge
warning
bool_1
0: Deactivat-
ed
1: Active
parAveragingEdgeDistance
(only for Bulkscan
®
LMS511)
Averaging filter (bulk edge
and conveyor belt edge)
13.1.10
Digital inputs
Permissible commands:
sRN, sWN
Variable name
Description
Variable
type
Value range
Unit
parUseBeltMoving
Use status signal for
the belt operation
bool_1
0: Deactivated
1: Active
DI1Logic
Logic of the status
signal for the belt
operation
uint_8
0: Active high
1: Active low
DI2Logic
Switching condition:
Reset volume sum
and mass sum
uint_8
0: Rising edge
1: Falling edge
13.1.11
Digital outputs
Permissible commands:
sRN, sWN
Variable name
Description
Variable
type
Value range
Unit
out1Assignment
out2Assignment
out3Assignment
out4Assignment
1)
out5Assignment
1)
out6Assignment
1)
Assignment of the
digital outputs (1
to 6).
(Bulkscan® LMS111
only 1 to 3)
uint_8
0: Off
1: Information/
warnings
2: Volume quota
3: Mass quota
4: Volume flow rate
5: Mass flow rate
6: Center of gravity
7: Bulk height
8: Bulk density
9: Belt speed
DO1Logic
DO2Logic
DO3Logic
DO4Logic
1)
DO5Logic
1)
DO6Logic
1)
Logic of the digital
outputs (1 to 6).
(Bulkscan® LMS111
only 1 to 3)
uint_8
0: Active high
1: Active low
outVolumeQuota
Volume quota per
pulse
float_32
0.01 to 10
6
m³/Inc
outMassQuota
Mass quota per pulse
float_32
0.01 to 10
6
t/Inc
1)
O
nly Bulkscan
®
LMS511