O P E R AT I N G I N S T R U C T I O N S | Bulkscan®
8014829/ZV98/2018-05-07 | S I C K
Subject to change without notice
5 2
ELECTRICAL INSTALLATION
6.3.2
Wiring floating digital inputs
IN1 or IN2
GND IN
External signal source
V
IN
= 11 … 30 V DC
Bulkscan® LMS511 /
Bulkscan® LMS111
Fig. 36: Wiring floating digital inputs
The inputs require a switching voltage of at least 11 V. For this reason the supply volt-
age must be at least 11 V.
6.3.3
Wiring encoder inputs
Encoder
Bulkscan® LMS511 /
Bulkscan® LMS111
ENC1
ENC2
GND ENC
A (0°)
B (90°)
GND Encoder
V
S
Encoder
Fig. 37: Wiring encoder inputs
The encoder requires its own power supply (V
S
encoder and GND encoder).
Note
Note