O P E R AT I N G I N S T R U C T I O N S | Bulkscan®
8014829/ZV98/2018-05-07| S I C K
Subject to change without notice
3 3
MOUNTING
Possible ways of mounting the Bulkscan® LMS111:
• Direct mounting (see "5.3.7 Direct mounting of Bulkscan® LMS111“ on page 39).
• Mounting kit 1a: mounting bracket for mounting at the rear on wall or machine (see
"5.3.8 Mounting of Bulkscan® LMS111 with mounting kit 1a or 1b“ on page 39).
• Mounting kit 1b: mounting bracket for mounting at the rear on wall or machine, with
protection for the optics cover (see "5.3.8 Mounting of Bulkscan® LMS111 with
mounting kit 1a or 1b“ on page 39).
• Mounting kit 2: mounting bracket, only in conjunction with mounting bracket 1a or
1b, cross-wise adjustment possible (see "5.3.9 Mounting of Bulkscan® LMS111 with
mounting kit 2 or 3“ on page 41).
• Mounting kit 3: mounting plate, only in conjunction with mounting kit 2, lengthwise
adjustment possible (see "5.3.9 Mounting of Bulkscan® LMS111 with mounting kit
• As an alternative you can use a strong stable mounting bracket that provides adjust-
able alignment of the Bulkscan® LMS111 in the X- and Y axis.
5.3.1
Direct mounting of the Bulkscan
®
LMS511
The Bulkscan® LMS511 has four M6×8 threaded holes on the rear. They can be used
to mount the Bulkscan® LMS511 directly on the intended mounting surface.
M x 8
Fig. 13: Direct mounting
During mounting, observe the dimensional drawings (see "11.4 Dimensional drawings“
Note