UP-5900VS
DIAGNOSTICS SPECIFICATIONS
4 – 9
3-12. MAGNETIC CARD READER DIAGNOSTICS
This test program reads the magnetic card based on the ISO7811/1-5
standard and displays the data.
Pressing the Esc key returns to the service diagnostics menu.
1) MAGNETIC CARD READER CHECK
1
Checking content
The test program reads tracks 1 and 2 of the magnetic card (UKOG-
6718RCZZ) based on the ISO7811/1 ~ 5 standard, and displays the
data in ASCII code. There are two kinds of data patterns to be read.
To read the card data, the following setting is performed.
• Mode set
46h is set to PSC2 channel 1 mode set register. (IATA, 6bit)
74h is set to PSC2 channel 2 mode set register. (ABA, 4bit)
• Start mark set
45h is set to PSC2 channel 1 start mark register.
0Bh is set to PSC2 channel 2 start mark register.
• Interrupt reset
Test data is written to PSC2 channel 2 start mark register.
• Interrupt mask cancel 01h is written to PSC2 MCR mask register
to cancel mask.
In addition, setting for the PSC2 extension interruption is per-
formed.
When the card is scanned, the obtained data is written to the
FIFO buffer from the start mark to LRC in sequence. Then, the
card data is read by interrupt process.
After reading data, the FIFO buffer is reset.
2
Display
The above display is made when the card (UKOG6718RCZZ) is
passed through the MCR. In case of an error, the error code is dis-
played as follows:
3
Terminating method
Press the Esc key to terminate the test and return to the service
diagnostics menu.
3-13. SYSTEM SWITCH DIAGNOSTICS
The system switch information of the main PWB is displayed.
Pressing the Esc key returns to the service diagnostics menu.
1) SYSTEM SWITCH
1
Checking content
The system switch reads I/O address 7F0H every 10ms to display
the value of bit 7, 6, 0. The relationship between the bit and JP
switch is as shown in the table below.
Reference only (not for diagnostics)
2
Display
Each JP switch data is displayed at X. If the bit data is “1,” the dis-
play is “OFF”. If the bit data is “0,” the display is “ON”.
3
Terminating method
Press the Esc key to terminate the test and return to the service
diagnstics menu.
3-14. DRAWER DIAGNOSTICS
The drawer open and sensor test are executed.
The following menu is displayed. The highlighted cursor is moved by
the cursor keys (UP
2
and DOWN
4
) of the PS2 keyboard.
Move the cursor to the desired item, and press the Enter key to execute
the selected diagnostics program. When the selected diagnostics pro-
gram is completed, the display returns to the menu screen. Pressing the
Esc key returns to the service diagnostics menu.
TRACK 1:
IATA pattern
76 character 7bit/character (Max. 79 character)
TRACK 2:
ABA data pattern
28 character, 5bit/character (Max. 40 character)
MCR (Magnetic Card Reader) Check
SHARP TEST CARD 0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ0123456789 UKOG-6718RCZZ
0123456789012345678901234567
TRACK1:
TRACK2:
Magnetic Card Reader Check
TRACK 1 : BUFFER EMPTY
TRACK 1 : MCR ERROR
TRACK 2 : BUFFER EMPTY
TRACK 2 : MCR ERROR
Displayed when TRACK1 EMPTY CODE is returned.
Displayed when TRACK1 ERROR CODE is returned.
Displayed when TRACK2 EMPTY CODE is returned.
Displayed when TRACK2 ERROR CODE is returned.
Bit
7
6
0
7F0H
JP0
JP1
JP2
System Switch Diagnostics
JP0
JP1
JP2
X
X
X
Drawer Diagnostics
Drawer 1 Check
Drawer 2 Check
Содержание UP-5900
Страница 128: ...UP 5900VS PWB LAYOUT 10 1 CHAPTER 10 PWB LAYOUT MAIN PWB UPPER SIDE ...
Страница 129: ...UP 5900VS PWB LAYOUT 10 2 BOTTOM SIDE ...
Страница 130: ...UP 5900VS PWB LAYOUT 10 3 INVERTER PWB UPPER SIDE BOTTOM SIDE UPPER SIDE UPPER SIDE BOTTOM SIDE ...
Страница 131: ...UP 5900VS PWB LAYOUT 10 4 UPPER SIDE BOTTOM SIDE UPPER SIDE BOTTOM SIDE ...