UP-5900VS
DIAGNOSTICS SPECIFICATIONS
4 – 15
10) TARGET SECTOR WRITE/READ-VERIFY TEST
[Test conditions setting]
Similar to test 5). Cylinder range setting is 000 *0* (Final cylinder 2).
1
Checking content
For the cylinder range, the head number, and the sector number
area set in the above, write/read/verify is made.
When the write/read test is completed in the set range, it is counted
as 1 pass.
In case of an error during the above test, a retry is repeated up to
the set number of retries. Everytime an error occurs a retry is per-
formed up to the set number of retries and, error logging is made.
Logging is made for HD and DRAM.
When the “Error Stop” is set in the test condition setting, if an error
occurs during the above test, the error display is shown and the test
is interrupted. Press the space key to resume the test.
When the “Continue” is set, even if an error occurs, the error display
is made but the test is not stopped.
When “1 Pass” is set, a series of tests is made only once.
2
Display
Same as the previous (6). The following two points are different.
*
Cylinder range ?
[000
0
XXX] (XXX is inmost cylinder 2.)
*
Test mode: the
grid is displayed.
When data writing, WRITE is displayed in the
grid. When
data reading, READ is displayed.
3
Terminating method
Same as test 5).
11) HD PATCH TEST (UTILITY)
[Test conditions setting]
Similar to the previous 6). The cylinder range setting is 000
0
(Final
cylinder 2).
1
Checking content
The sector set in the above is displayed on the screen in the unit of
256 bytes.
Hex data and ASCII characters are displayed.
By key operation, the following 256 bytes data or previous 256 bytes
data can be displayed.
After changing data on the screen, data is written to the selected set
position.
2
Display
Similar to test 6). Data in the HDD can be patched.
Patching is made as follows:
To patch data in the HD, change data on the screen.
(Move the cursor with
2
,
4
,
1
,
3
, keys and enter data with 0 ~ F
key.
Then select “Yes” in “Up data ? [Yes/No]” and press Enter key.
(Move with
1
key.)
With the above procedure, patch is made.
3
Terminating method
Same as test 6).
12) ERROR LOGGING AREA CLEAR
1
Checking content
The last cylinder area in the HD is cleared with 00H.
(Error logging area: last cylinder, all sectors of 0 head)
The areas to be cleared with 00H is the last cylinder and all the sec-
tors of 0 head.
2
Display
Select “Yes” at position @ (move with the
1
key) and press the
Enter key to execute the test.
When the test is executed once, the mode enters the key waiting
mode. After executing the test, press the space key to execute
again.
3
Terminating method
Press the Esc key to return to the menu screen.
13) ERROR TABLE DISPLAY
When an error occurs during the above test, error information is stored
in the DRAM and the content is displayed.
If there is no error, OK or NO ERROR is displayed.
14) SUPPLEMENTAL ITEMS
Error information is stored up to 44 items in the sequence of occurrence
from when the function is selected. If the item number exceeds 44, the
error information is not stored any more.
15) ERROR CONTENT
The following error content is error information directly obtained from
the HDD controller.
[Error code and meaning]
Error code
Error message
0
OK (This message is displayed when the test is normally
completed.)
1
Drive not ready (HDD is not ready. STATUS REG bit 6 : 0)
2
Bad controller (HDD controller abnormality,diag status
error STATUS REG bits : 1 or DIAG STATUS >= 2)
3
Track 000 Error (TRACK 000 cannot be found with
RESTORE command. ERROR REG bit 1 : 1)
4
Seek Error (A seek error occurs. After STATUS COM-
MAND is executed,STATUS REG bit 4 : 0)
5
ID not Found (ID field is not detected. ERROR REG bit 4
: 0)
6
Data Address Mark not Found (Data Address Mark is
not found. ERROR REG bit 0 : 1)
7
Bad Block Detect (BAD block mark is stored in the ID
field of request sector. ERROR REG bit 7 : 1)
8
Uncorrectable error (An uncorrectable read error occurs.
ERROR REG bit 6 : 1)
9
Others error (The other error STATUS REG bit 0 : 1,and
ERROR REG : 0)
10
Time out error (Time out occurs when making access to
HDD.)
11
Compare error (The written data and the read data are
not the same.)
Error Logging Area Clear
@Test Start ? [Yes No]
, : Move ESC : Exit ENTER : Select
ESC : Exit SPACE : Retry
At first No is highlighted.
Guidance before execution of the test
Guidance after execution of the test
Содержание UP-5900
Страница 128: ...UP 5900VS PWB LAYOUT 10 1 CHAPTER 10 PWB LAYOUT MAIN PWB UPPER SIDE ...
Страница 129: ...UP 5900VS PWB LAYOUT 10 2 BOTTOM SIDE ...
Страница 130: ...UP 5900VS PWB LAYOUT 10 3 INVERTER PWB UPPER SIDE BOTTOM SIDE UPPER SIDE UPPER SIDE BOTTOM SIDE ...
Страница 131: ...UP 5900VS PWB LAYOUT 10 4 UPPER SIDE BOTTOM SIDE UPPER SIDE BOTTOM SIDE ...