LINE FILTER (con’t)
6. Reconnect the power cord to the machine.
Note: There will be exposed 120 VAC. Use
extreme caution when working with exposed wires.
7. With a DVOM configured to measure 120 VAC,
contact the red probe to the L pin and the Black
probe to the N pin. If 120 VAC is not indicated,
the Line Filter is defective or no power is
reaching the machine.
8. Unplug machine from any power sources.
9. Reconnect spade connectors to the Line Filter
(Figure 3-43).
10. Replace the seven screws for the Mandrel
Support Plate but do not tighten down.
11. Hand tighten the four top screws, ensuring that
the end of the Material Roll Mandrel is sitting
inside the recessed circle of the Mandrel
Support Plate (Figure 3-44).
12. Tighten all screws with an Allen Wrench.
GRN-Earth
BLK-L
BLU-N
Figure 3-43. Wire colors and locations
Figure 3-44. Mandrel Support Plate alignment
Recessed
Circle
USE EXTREME CAUTION WHILE SERVICING A
MACHINE WHILE POWER IS APPLIED.
UNEXPECTED MACHINE STARTUP CAN
CAUSE SERIOUS INJURY.
WARNING
DO NOT ATTEMPT TO SERVICE THE MACHINE
DURING NORMAL OPERATION. KEEP HANDS
AND ARMS CLEAR OF MOVING PARTS.
WARNING
WHEN TESTING ELECTRICAL COMPONENTS
WHILE POWER IS APPLIED TO THE MACHINE,
USE PROPER TROUBLESHOOTING
TECHNIQUES TO AVOID ELECTRICAL SHOCK.
WARNING
Always remove electrical power from the
SX
prior to performing any maintenance
on the machine.
WARNING
SX
™
Service and Maintenance Manual 3-17 960714-02B © 2007 I2407
SECTION 3 – COMPONENT REPAIR
ELECTRICAL COMPONENTS