SECTION 3 – COMPONENT REPAIR
UNWIND ASSEMBLY
UNWIND SPRING (con’t)
4. Slide the new spring onto the shaft. The end of
the spring is to be inserted into the slot on the
rear side of the hole in the middle unwind plate
(Figure 3-372).
5. Slide the unwind shaft into position. The
exposed end of the spring is to be inserted into
the machined slot on the back side of the
unwind shaft flange (Figure 3-373).
6. With the shaft completely slid onto the
machine, reinsert the four mounting screws for
the unwind bearing plate (Figure 3-374).
7. Reinstall the nylon washer and the E-Clip on
the end of the unwind shaft.
Middle Unwind
Plate Spring Slot
Figure 3-372. Inserting the Unwind Spring
Unwind Shaft
Spring Slot
Figure 3-373. Inserting the Unwind Spring
Figure 3-374. Unwind Plate Mounting Screws