SX™
Service and Maintenance Manual 3-143
960714-02B © 2007 I2407
SECTION 3 – COMPONENT REPAIR
SEALER ASSEMBLY
JAW POSITION SENSORS (con’t)
1. Remove the guards identified in Figure 3-365.
2. Remove the mounting screws for the sensor
bracket that needs replacement. Once free,
access the sensor through the rear of the
machine. Follow the wire routing through the
machine, and remove any wire ties as
necessary.
3. Locate the 6-position junction box, and unplug
the connector in port 1 for the “Near Home”
Sensor and/or port 2 for the “Home Sensor.
This should free the sensor completely from
the machine. Gently pull the wire, being
careful of other wires still in the machine
(Figure 3-367).
4. Remove the sensor mounting screw from the
block, and install the new sensor in the
orientation shown in Figure 3-368.
REPLACEMENT
Figure 3-365. Guard Identification
Front
Guard
Load
Plate
Outside
Frame
Guard
Motor
Cover
Left
Sealer
Guard
Figure 3-366. “Near Home” Sensor Mounting Screw
Jaw Sensor Mounting Screws
6-Position
Junction Box
Figure 3-367.Stripper Plate Sensor Plugs
Figure 3-368. Sensor Mounting Block