SX™
Service and Maintenance Manual 3-125
960714-02B © 2007 I2407
SECTION 3 – COMPONENT REPAIR
SEALER ASSEMBLY
STRIPPER PLATE ASSEMBLY (con’t)
6. Remove the front finger plate from the
machine.
Do not pull the plate away from the
machine too quickly, as the photoelectric
eye is attached to the plate and wired to the
machine.
Gently place the plate under the
rollers, ensuring the sensor wire is not
excessively pulled (Figure 3-315).
7. Remove the eight bolts identified in figure 3-
316 to unfasten the heater block from the
middle horizontal plate. Once the screws are
removed, the heater block will be free to hang
loose inside of the machine, but cannot be
removed as it will still be held by wires. Gently
let the heater block hang inside of the machine.
8. Remove the eight spring block mounting
screws.
9. Remove the stripper plate assembly from the
machine. Being sure the pressure jaw is
completely open, slowly slide the stripper plate
to the front of the machine until the spring
blocks hit the front plate. Through the opening
created by removing the front guard, reach in
and turn the spring blocks 90°. This will allow
the complete stripper plate assembly to be
removed from the machine by continuing to
slide it forward (Figure 3-318).
Figure 3-315. Front Finger Plate
Front Finger
Plate Screws
Figure 3-316. Heater Block Mounting Screws
Note: Viewed from Rear; Cradle Removed for Clarity
Figure 3-317. Spring Block Mounting Screws
Note: Viewed from Rear; Cradle Removed for Clarity
Figure 3-318. Removing the Stripper Plate
Note: Sealer Assembly Isolated for Clarity; Stripper
Plate shown in Red, Horizontal Mounting Plate Shown
in Blue
Spring Blocks
Turned 90°