SX™
Service and Maintenance Manual 3-135
960714-02B © 2007 I2407
SECTION 3 – COMPONENT REPAIR
SEALER ASSEMBLY
STRIPPER PLATE SENSORS
The stripper plate sensors are part of the
Obstruction Sensing Jaw. The two sensors are
located inside the machine on each end of the
stripper plate, and are activated by flags on the
plate. If they are not working, the machine will go
into a jaw fault and will not cycle.
Some of the procedures in this section require that
the electrical power to the machine remain ON.
1. Remove the outside frame guard (Figure 3-
342).
2. Locate the 6-positon junction box. Ensure the
plugs are fully inserted into the ports. The left
stripper plate sensor will be in the receptacle
numbered ‘5’ and the right sensor will be in
receptacle ‘6’ (Figure 3-343).
TESTING
USE EXTREME CAUTION WHILE SERVICING
A MACHINE WHILE POWER IS APPLIED.
UNEXPECTED MACHINE STARTUP CAN
CAUSE SERIOUS INJURY OR DEATH.
WARNING
DO NOT ATTEMPT TO SERVICE THE
MACHINE DURING NORMAL OPERATION.
KEEP HANDS AND ARMS CLEAR OF
MOVING PARTS.
WARNING
WHILE TESTING ELECTRICAL
COMPONENTS WITH POWER APPLIED TO
THE MACHINE, USE PROPER
TROUBLESHOOTING TECHNIQUES TO
AVOID ELECTRICAL SHOCK.
WARNING
Figure 3-342. Guard Identification
Outside
Frame
Guard
Left Sensor Plug
(Receptacle 5)
Right Sensor Plug
(Receptacle 6)
Figure 3-343.Stripper Plate Sensor Plugs